New York City’s FISP program requires recurring exterior-wall and appurtenance inspections and electronic technical-report filing for buildings higher than 6 stories.
Understand what applies.
Use this summary as a starting point. Walker can help confirm the current requirements, determine the appropriate inspection approach, and support the filing process for your building.
Buildings generally covered
Buildings higher than 6 stories.
Typical inspection cadence
Every 5 years. Filing windows are tied to the building block number.
Qualified professional
A Qualified Exterior Wall Inspector (QEWI).
Filing notes
Technical façade reports are filed electronically through DOB NOW: Safety. Confirm the current cycle, subcycle, filing window, and unsafe-condition rules with NYC DOB.
Unsafe-condition requirements
Confirm the jurisdiction-specific requirements, repair deadlines, emergency actions, and amended-report obligations when unsafe conditions are identified.
Requirements can change. Confirm current applicability, filing deadlines, and professional requirements with the local jurisdiction or a qualified professional before relying on this summary.
How Walker helps.
Confirm the ordinance, building criteria, filing cycle, and inspection requirements.
Walker selects an inspection approach based on the ordinance, building geometry, access needs, and observed conditions. Methods may include visual assessment, close-up review, swing stages, aerial lifts, drones, or rope access.
Translate findings into clear documentation and support the appropriate reporting process.
Walker can support repair design, construction documents, bidding assistance, and construction administration when the inspection identifies conditions that need to be addressed.
Related Walker location: New York, NY
Local Walker expertise.
Featured Expert
Director of Building Envelope
Frequently asked questions.
New York City’s FISP program requires recurring exterior-wall and appurtenance inspections and electronic technical-report filing for buildings higher than 6 stories.
Buildings higher than 6 stories.
Every 5 years. Filing windows are tied to the building block number.
A Qualified Exterior Wall Inspector (QEWI).
Yes. Walker can help confirm what applies, complete the inspection, document conditions, and support the required reporting process. Technical façade reports are filed electronically through DOB NOW: Safety. Confirm the current cycle, subcycle, filing window, and unsafe-condition rules with NYC DOB.
Walker can support repair design, construction documents, bidding assistance, and construction administration when the inspection identifies conditions that need to be addressed.
Need help confirming what applies?
Tell us where the property is located and what you know about the building. Walker can help confirm the ordinance requirements, inspection approach, and filing path.